Metallic Pipe Fiberglas® Tape FT-1, FT-2 Self Regulating Heating Cable • Low Te

Metallic Pipe Fiberglas® Tape FT-1, FT-2 Self Regulating Heating Cable • Low Temperature SRL, HSRL, SRF • Medium Temperature SRM/E, HSRM Metallic Pipe Weatherproof Jacket Thermal Insulation Fiberglas® Tape FT-1, FT-2 Self Regulating Heating Cable • Low Temperature SRL, HSRL, SRF • Medium Temperature SRM/E, HSRM Fiberglas® Tape FT-1, FT-2 Self Regulating Heating Cable • Low Temperature SRL, HSRL, SRF • Medium Temperature SRM/E, HSRM For multiple heaters place control sensor 90° from nearest heater or centered between equally spaced heaters. Control Sensor Self Regulating Heating Cable • Low Temperature SRL, HSRL, SRF • Medium Temperature SRM/E, HSRM 45° Thermal Insulation Top Weatherproof Jacket Cable located at nominal 45° below horizontal centerline. Cable located at nominal 45°below horizontal centerline on either side. 45° Top 90° Top 45° Step 1 Start tracing at the end of the pipe and work your way back to spool. Step 2 Leave a loop of cable at heat sinks such as valves, pipe supports and flange set. Use FT-1 Fiberglas® tape to secure cable to pipe at 18˝ intervals. Step 3 Fiberglas® Tape FT-1, FT-2 Temperature Control & Power Connection Box (RTPC) Heating Cable Insulation Cable End Seal (RTES) Pipe Strap T ee Box (RTST) Heating Cable/Sensor Location Electric Heat Trace Quick Install Guide Quick Install Guide is a specification tool only. Always refer to proper installation instructions when installing heat trace cable. Ask about Chromalox Class 1 Div. 1 Cables & Accessories as well as a full line of High Temperature Cables. Installation Tips • Temporarily position cable on pipe and equipment to ensure proper distribution. • Leave a loop of cable at heat sinks such as valves, pipe supports and flange sets. Use FT-1 Fiberglas® to secure cable to pipe at 18˝ (nom) intervals using recommended method. • Always observe minimum bend radius. • 1,2,8,12 and 24 loops • Pre-wired and assembled control, monitoring & distribution (saves time on installation) • Intuitive color touch screen interface (saves time on programming) CONTROL SYSTEMS FOR TECHNICAL SUPPORT CALL 888-996-9258. © Copyright 2002 Chromalox®, Inc. Plastic Pipe Fiberglas® Tape FT-1, FT-2 Self Regulating Heating Cable • Use Low Temperature SRL, HSRL, SRF Cable Aluminum Tape AL-1 Plastic Pipe Installation Metallic Pipe Self Regulating Heating Cable • Low Temperature SRL, HSRL, SRF • Medium Temperature SRM/E, HSRM Spool Fiberglas® Tape FT-1, FT-2 Note: Aluminum tape must be used under or over heating cable to spread heat transfer. Combination Single Point Temperature Controls & Power Connection Boxes • 0°–225°F Temp. Rating • 120–480 VAC, 22A Switching Capability • Freeze Protection Applications • 0°–400°F Set Points • 120–480 VAC, 22A Switching Capability • Process Temperature Applications RTAS Ambient-Sensing RTBC Line-Sensing Pipe Support 3˝ Typical Metallic Pipe Support Shoe Fiberglas® Tape FT-1, FT-2 Self Regulating Heating Cable • Low Temperature SRL, HSRL, SRF • Medium Temperature SRM/E, HSRM Step 1 Step 2 Metallic Pipe Fiberglas® Tape FT-1, FT-2 Caution Labels uploads/s3/ cable-guide 1 .pdf

  • 25
  • 0
  • 0
Afficher les détails des licences
Licence et utilisation
Gratuit pour un usage personnel Attribution requise
Partager